VANNER Incorporated Specifications
70-Series Power Management System OWNER’S MANUAL
4
Specifications
70-Series Equalizers
Model Number
70-60M
70-80M
70-100M
Input Voltage 24v
18 to 32 v
Efficiency (Peak)
>97%
>97%
>97%
Max 24v Input Amps
32
43
53
Output Voltage
(Input Voltage/2) ±2%
Output Amps (12v)
0-60
0-80
0-100
Standby Current
17 milliamps nominal at 28.4V
Electronic Monitor
Alarm Low/High, Imbalance, Undervoltage protect override, Vann-Guard fault
Operating Temp.
-40°C to +75°C (-40°F to 167°F)
Storage Temp.
-54°C to +95°C (-65°F to 203°F)
Serviceable
Yes
Yes
Yes
Environmental
Considerations
Cast aluminum enclosure provides protection against salt, fungus, dust, water, fuel vapors and all fluids associated with
commercial and off-highway vehicle operations. IP rated 56.
Mounting Location
Mount on a flat surface close to the batteries to allow short cable runs. Location should be protected from battery acid
and gases.
Weights
8.7 lbs.
8.9 lbs.
9.3 lbs.